Prevent's Overview page shows you which sensors are broken down by group (in the top grid) and most frequently (in the bottom charts). In Prevent, go to Observation > Overview.
Show activated sensors only shows and hides sensors with zero results and is marked by default. Clear the checkbox to see all the sensors that are being monitored by SysTrack.
Show Only System Checklist Sensors (cleared by default) filters the results to only show System Checklist Sensors. This filter only applies to the Sensor Overview table. These sensors will still show under their Sensor Category.
In Time Frame, select Active systems (default) or Latest result per system to see the latest results for every system, even the systems that are not currently active. The Time Frame applies to the whole page.
Sensor Overview
This table provides an overview of the number of sensors activated, broken down by Sensor Category and Groups. By default, the table will show sensor information for the top 10 largest groups. Under each group name, the table shows the number of active systems and the total number of systems in the group (for example, 85 / 100).
Sensor Column
The sensors in the far left Sensor column are listed in collapsible tree format. You can expand the rows to see each individual sensor that was activated in each category.
.png?sv=2026-02-06&spr=https&st=2026-11-29T02%3A59%3A55Z&se=2026-11-29T03%3A11%3A55Z&sr=b&sp=r&sig=56CAC9pXS6xiStKJL7VePxlBWYfT0yQOI7gBSOSNdTc%3D)
NOTE: Double-click a sensor to view more information on data for all systems for that sensor on the Sensor Details page.
All Systems Column
The All Systems column shows all systems that are reporting sensor activity.
Group Columns
The other columns are groups as defined in Configure or Deploy.
A yellow cell means the sensor is active on more than 5 percent of the systems in that group.
A red cell means the sensor is active on more than 10 percent of the systems in that group.
The sensors are automatically sorted alphabetically. You can click any column header to sort the sensor values from lowest to highest or highest to lowest.
Double-click any sensor name or double-click in the grid, single click from the most common sensors graph to view more detailed information about that sensor/value on the Sensor Details page. The problem systems graph will take you to system details.
Change Groups
Go to Prevent > Observation > Overview.
Click Change Groups. The System Groups dialog box displays.
.png?sv=2026-02-06&spr=https&st=2026-11-29T02%3A59%3A55Z&se=2026-11-29T03%3A11%3A55Z&sr=b&sp=r&sig=VKLgl3HDwSQPub6P9MtnFrad45aoROVDRbXfqOWw%2Bzo%3D)
Select groups that you would like to see or enter text to search for a specific group.
NOTE: You can select up to 10 groups.
Click Update Groups. The Overview page updates to display the groups you selected.
If you clear all groups, the button changes to Show Default Groups. Click it to show the 10 largest groups again.
Top Sensors and Systems
.png?sv=2026-02-06&spr=https&st=2026-11-29T02%3A59%3A55Z&se=2026-11-29T03%3A11%3A55Z&sr=b&sp=r&sig=iHabXQsayikxeQTGfHnF%2F3ZIGC06J%2BJnDPJQRy6PSzQ%3D)
Most Common Sensors
This graph shows the ten most common sensors in the selected timeframe. If you click a bar in the Most Common Sensors graph, you will arrive on the Sensor Details page for more detail about that sensor.
Problem Systems
This graph shows the ten systems that currently have the most active sensors. If you click a system in the Problem Systems graph, you will arrive on the System Details page for more detail about that system.