Install the Microsoft Visual C++ Redistributable before you install the SysTrack agent. Install them in this order:
VC_redist.x86.exe, on 32-bit and 64-bit operating systems.
VC_redist.x64.exe, on 64-bit operating systems only.
The SysTrack agent, Systems Management Agent_x32.msi. See On-Premises Standard Installation.
IMPORTANT: Install prerequisites before installing the SysTrack Agent. For the non-persistent desktop, install, reinstall, upgrade, and uninstall on the golden image.
Prerequisites for both 32-bit and 64-bit
Initial Install, Reinstall, and Upgrade
Install VC_redist.x86.exe on both 32-bit and 64-bit operating systems.
From the child system, open a command prompt (select Run as administrator) and type the following command:
VC_redist.x86.exe /q /norestart /log <enter path to an existing folder>\VC2019x86.log (log is optional)
Prerequisites for 64-bit only
Install, Reinstall and Upgrade
Install VC_redist.x64.exe on 64-bit operating systems.
From the child system, open a command prompt (right-click and select Run as administrator) and type the following command:
VC_redist.x64.exe /q /norestart /log <enter path to an existing folder>\VC2019x64.log (log is optional)
Switches Information
/q– Quiet mode: no user input required or output shown/norestart: If the operation requires a reboot, setup will not prompt or cause a reboot./log: Location of the log file. Use this switch to create a log file in a specific location.
It is not required to use the /log switch. By default, vcredist automatically creates default logs in or near %temp% with a name based on the package, date and time. For example:
dd_vcredist_amd64_<date><time>.log
dd_vcredist_amd64_<date><time>_<number>_vcRuntimeAdditional_x64.log
dd_vcredist_amd64_<date><time>_<number>_vcRuntimeMinimum_x64.logSilent Installation
If you are performing a silent installation (using the /q switch), view the progress in the Task Manager.
VC_redist.x86.exe or VC_redist.x64.exe is listed when running.
Once the installation completes, the name is removed.
Determine if the installation was a success or failure by reading information near the bottom of the log. For example:
MSI (s) (1C:30) [09:32:38:394]: Product: Microsoft Visual C++ 2019 X86 Additional Runtime - 14.24.28127 -- Installation completed successfully.
MSI (s) (1C:30) [09:32:38:394]: Product: Microsoft Visual C++ 2019 X86 Minimum Runtime - 14.24.28127 -- Installation completed successfully.
MSI (s) (1C:30) [09:32:38:394]: Product: Microsoft Visual C++ 2019 X64 Additional Runtime - 14.24.28127 -- Installation completed successfully.
MSI (s) (1C:30) [09:32:38:394]: Product: Microsoft Visual C++ 2019 X64 Minimum Runtime - 14.24.28127 -- Installation completed successfully.If the log indicates that the installation failed, search for return value 3 to determine the cause of the failure.
If the installation fails, see Troubleshoot a Failed Agent Installation.
System Reboot
To determine if a system reboot is needed, search the log for entries that indicate a system reboot is required. Keywords to search for are: system restart and reboot.
Info 1903.Scheduling reboot operation: Deleting file c:\Config.Msi\3c4d50f.rbf. Must reboot to complete operation.
MSI (s) (EC:A0) [16:38:48:595]: The Windows Installer initiated a system restart to complete or continue the configuration of...If a reboot is required, restart the system before you install the SysTrack agent. To check the agent installation itself, see Successful Installation.